beautypg.com

AFX ALS1606218QMVSNLA User Manual

Algiers sconce, Fluorescent fixture, Safety precautions

background image

Algiers Sconce

Fluorescent Fixture

Model: ALS218MV

Page 1 of 1

8060687 R2

Limited Factory Warranty
AFX Lighting, Inc. warrants this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions
for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or
components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.

It is recommended that all wiring be performed by a qualified
electrician. This fixture must be wired in accordance with all national
and local electrical codes.

Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.

Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing).

Model numbers ending in

MV are designed for use in a 120-277VAC, 60Hz fused circuit (Do
not use on a dimming circuit).
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel.

This fixture is intended to be used for general indoor lighting in dry
or damp locations only.

Assembly Instructions

1.

Preparing for installation

A. Disconnect electrical power before installing or servicing any part of this fixture.
B. Remove fixture from carton; remove backplate (5) and diffuser assembly (9).

2.

Wiring

All wiring must take place inside junction box.

Caution

: Make sure power is off at fuse or circuit breaker box. Check

power wires for damage or scrapes. If power supply wires are within three inches of ballast use wire suitable for at least 90C (194F).
Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing.

A. This unit will not operate properly unless connected to a “grounded” electrical circuit. Electrical shock, over heating, low or no

light output, and shortened lamp life can result if proper grounding is not done. Securely attach green (or green and yellow) wire
to ground supply wire.

B. The black wire from the fixture is connected to the black wire from power source.
C. The white wire from the fixture is connected to the white (neutral) wire from power source.
D. Pull on each wire to make sure connections are secure. Make certain no bare wires are exposed outside of wire connectors.
E. Tuck all connections neatly into junction box.

3.

Mounting

A. Thread nut (3) on stem (4). Adjust the length of

the stem in gem bar so that approx. 3/4” length
is exposed.

B. Install gem bar (1) (provided) on the junction

box (not provided) by securing it with two (2)
screws (provided).

C. Install backplate (5) by securing it with

thumbnut (6) on stem (4).

4.

Lamps

A. Install compact fluorescent lamps (7) (not included) into

the sockets (8).

5.

Diffuser mounting

A.

Align diffuser (9) mounting holes with the two
ceiling pan threaded bushing (11).

B.

Install diffuser assembly (9) by securing it with two
(10) screws (provided).

6.

Power to the fixture can now be restored.

This manual is related to the following products: