AFX DEP126SNEC User Manual
Dep series, Fluorescent pendant fixture, Safety precautions

DEP Series
Fluorescent Pendant Fixture
Model 126 
 
Page 1 of 1
8060539 Rev 1
Safety Precautions
Read all safety precautions and installation instructions carefully 
before installing or servicing this fixture. Failure to comply with 
these instructions could result in potentially fatal electric shock 
and/or property damage. 
 
It is recommended that all wiring be performed by a qualified 
electrician. This fixture must be wired in accordance with all national 
and local electrical codes. 
 
Do not handle any energized fixture or attempt to energize any 
fixture with wet hands or while standing on a wet or damp surface or 
in water. 
This fixture is designed for use in a 110-120VAC, 60Hz fused circuit. 
Do not use on a dimming circuit. 
 
To reduce the risk of electrical shock, and to assure proper operation, 
this fixture must be adequately grounded. Make sure to connect the 
canopy (8) ground wire to the incoming earth ground from your main 
power supply panel. 
 
This fixture is intended to be used for general indoor lighting in dry 
locations only. 
Assembly Instructions
1.
Preparing for installation.
A. Disconnect electrical power before installing or servicing any part of this fixture. 
B. Insert one set of #8-32 x 1-1/2 screws (9) through the top of gem bar (10) with the 
threaded portions facing down to line up with the mounting holes in the canopy (6).
C. Attach gem bar (10) to junction box (not provided) in position shown with #8-32 x 1-1/2
screws (8) provided. Note: Allow access into junction box to complete wiring.
2.
Wiring
All wiring must take place inside junction box. Caution: Make sure power is off at fuse or 
circuit breaker box. Check power wires for damage or scrapes. If power supply wires are 
within three inches of ballast use wire suitable for at least 90C (194F). Note: Most dwellings 
built before 1985 have supply wire rated to 60C. Consult a qualified electrician before 
installing. 
A. Feed cord (4) through strain relief (7) and center hole in canopy (6). 
B. Connect the green ground pig-tail wire attached to the canopy to the supply ground wire 
and secure with a wire nut (11).
C. To modify cord length, unscrew strain relief cover (7) from canopy (6). Pull cord (4)
through canopy to desired length. Secure cord by re-attaching strain relief cover.
D. Determine desired cord (4) length for fixture. 
E. Once desired mounting length is determined, cut cord allowing for 6 inches of wire for 
junction box wiring. Carefully remove outer insulation from cord without damaging lead 
wires. Strip lead wires back 3/8 inch for wire nut connections. WARNING: Inspect 
modified cord and wires for any damaged insulation. 
F. Using wire connectors (11) provided, connect white (Common/Neutral) supply wire to
one clear fixture lead. Connect black (Hot/Incoming) supply 
wire to the other clear fixture lead. Pull on each wire lead to 
make sure connections are secure. Make certain no bare wires 
are exposed outside of wire connectors. 
3.
Mounting
A. Tighten gem bar mounting screws (8). 
B. Align canopy (6) over mounting studs (9) and fasten with 
thumbnuts (5).
C. Tighten strain relief cover (7) to set desired length of cord (4).
4.
Lamping/Re-lamping
A. Lift decorative cap (2) and glass diffuser (1) up to expose lamp-holder (13). Install appropriate 26
watt 4-pin fluorescent quad lamp G24q-3 (14) into barrel ballast (12), then install the barrel ballast 
with lamp onto the socket (13) by aligning pins and turning clockwise until it stops. Carefully slide 
glass and decorative top down to diffuser stop (3).  
B. Restore power at fuse or circuit breaker box.
Limited Factory Warranty 
American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating 
conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it 
does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.