Taf series, Linkable fluorescent ceiling fixture – AFX TAF16155C530MVPC User Manual
Page 2
TAF Series
Linkable Fluorescent Ceiling Fixture
Model 155
Page 2 of 2
8060535 Rev.2
FIGURE 4
5. Preparing for Additional Fixture Linking
NOTE: Wire way channel creates a fixed 3 ¾” spacing between ceiling pans.
A. Locate and remove appropriate knock-out on the back-pan (1)
.
B. Hold up second fixture and mark appropriate knock-out in line with first
hardwired fixture.
C. Remove the knock-out on linked unit and insert one end of wire way
channel (12) into the knock-out from the first hardwired unit. Secure the
wire-way channel with the thumb screw (10 - provided) inside the
diffuser.
6.
Linking Additional Fixtures
A. (See figure 5) Align wire-way channel into second fixture knock-out and
mark keyhole mounting locations. Verify flange from wire-way channel
is flush on both fixtures.
B. Take the linking fixture down and locate the ceiling joists with a stud
finder or punch a small hole into the ceiling at each location; using a nail,
verify there is a wood joist. If there is a joist, use a suitable wood screw
(not included) to mount the channel. Where there is no joist to screw
into, use a ¼” toggle bolt (not included) of suitable length to mount
channel securely to the ceiling.
C. Secure the wire-way channel with the thumb screw (10 - provided)
inside the diffuser.
D. Attach linked fixture connector (7) to connector (11) on the inside of
each fixture to link fixtures. Maximum number of linkable fixtures:
10 units.
7. Fixture Lamping
A. This fixture uses one FC12T5 55W high output circline lamp (5 -
provided).
B. Align lamp (5) pins into socket. Press lamp into lamp clips until lamp
is secured at all locations. Press lamp pins into socket until pins snap
in place and are secured.
8. Bottom Diffuser Installation
A. (See figure 6) Assemble lower diffuser by inserting one corner into the
inside of the base diffuser allowing it to rest on the inside edge.
Lift up the rest of the diffuser edges and allow the lower diffuser to
rest on inside of the main diffuser edge.
9. Restore power at fuse or circuit breaker box
FIGURE 6
FIGURE 5
Limited Factory Warranty
American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used
under normal operating conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to
replacement of defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in
transit.