American Dryer Corp. SL20 User Manual
Page 9

113191-2
7
Note
Component failure due to improper installation will
void the warranty.
The use of aluminum wire will void the warranty.
Important
Failure to comply with these codes or ordinances,
and/or the requirements stipulated in this manual
can result in personal injury or component failure.
Each circuit must be connected to an independently protected
branch circuit.
Use only copper conductor cable of proper ampacity and
insulation in accordance with electric codes for making service
connections.
A separate circuit servicing each dryer must be provided.
Electrical Service Specifications
Important
The wire size must be properly sized to handle the
related current.
The dryer must be connected to the electric service/
supply shown on the dryer data label.
Note
Manufacturer reserves the right to make changes in
specifications at any time without notice or obligation.
Component failure due to improper voltage
application will void the warranty.
Gas Models
1/22/04
!
!
!
!
Electric Models
The connecting wires must be properly sized to handle the
rated current.
1/22/04
Grounding
A ground (earth) connection must be provided and installed
in accordance with state and local codes. In the absence of
these codes, grounding must conform to applicable
requirements of the National Electrical Code ANSI/NFPA NO.
70-LATEST EDITION, or in Canada, the installation must
conform to applicable Canada Standards: Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
The ground connection may be to a proven earth ground at
the location service panel.
For added personal safety, when possible, it is suggested
that a separate ground wire (no. 18 minimum) be connected
from the ground connection of the dryer to a grounded cold
water pipe. Do not ground to a gas pipe or hot water pipe.
The grounded cold water pipe must have metal-to-metal
connection all the way to the electrical ground. If there are
any nonmetallic interruptions, such as, a meter, pump, plastic,
rubber, or other insulating connectors, they must be jumped
out with no. 4 copper wire and securely clamped to bare
metal at both ends.
Important
For personal safety and proper operation, the dryer
must be grounded.
Provisions are made for ground connection in each dryer at
the electrical service connection area.
Note
An individual manual shutoff valve must be installed
within 6 feet (1.8288 meters) of the dryer in
accordance with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
GAS
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
NOTES: A.
B.
C.
When fuses are used they must be dual element, time
delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying
either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor
curve type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating
and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be
3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
120
1ш
2
8.4
---
15
208
1ш
2
4.3
---
15
230
1ш
2
---
4.8
15
240
1ш
2
4.7
5.0
15
ELECTRIC
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
NOTES: A.
B.
C.
When fuses are used they must be dual element, time
delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying
either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type
ONLY. For others, calculate/verify correct breaker size
according to appliance amp draw rating and type of
breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be
3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
208 (4.1 kW)
1ø
2
24.0
--
30
208 (6.1 kW)
1ø
2
33.6
--
40
230 (5.0 kW)
1ø
2
--
26.0
30
230 (7.4 kW)
1ø
2
--
36.5
45
240 (5.4 kW)
1ø
2
27.2
27.5
30
240 (8.1 kW)
1ø
2
38.5
38.8
45
380 (6.8 kW)
3ø
4
--
14.9
20
400 (7.5 kW)
3ø
4
--
15.6
20
416 (8.1 kW)
3ш
4
--
16.2
20
!
!