QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 18.
QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 18.
S U B T I T L E
T I T L E
C A U T I O N
ADEQUATE SPACING MUST
BE ALLOWED BETWEEN PANS
FOR PROPER AIR CIRCULATION
FOR BOTH PROCESSING AND
SUBSEQUENT HOLDING.
A D V A N C E D O P E R A T I O N
O P E R A T I O N
The date and time will appear in the display when
the unit is off. When the unit is turned on, the
screen will read: “SELECT MODE OR PRESS
START TO SELECT PRESET
”
To initiate any Quickchiller operating mode,
power must initially start from the
off
position
or an operating mode must be halted by pressing
the START/STOP key so that the SELECTION
SCREEN
appears on the display.
NOTE:
With the exception of the QC-3 counter
top Quickchiller model, the Alto-Shaam
name on the control panel will illuminate
whenever the power key is pressed to the
on
position.
HOLD TEMP
Starting from the
off
position, press the
power key
on
. The SELECTION SCREEN
will appear on the display. The compressor
will become energized and will begin to
operate if required by the sensors.
Press the HOLD TEMP key. The display
will indicate the default hold temperature
(changeable in User Settings).
To change the displayed temperature, press the
up
5
or down
6
arrow key to increase or decrease
the temperature display within the refrigeration
storage parameters of the Hold Temp mode -5°F to
+40°F (-21°C to +4°C).
note
:
THE
MOdIfIEd
HOLdINg
TEMPERATURE
SET
-
POINT
IS
NOT
SAVEd
.
THE
dEfAULT
HOLd
TEMPERATURE
CAN
bE
CHANgEd
UNdER
USER
SETTINgS
.
Press the START/STOP key to begin
operation of the Quickchiller in the Hold
Temp mode.
The display will indicate:
1. The length of time the chiller is
operating in the Hold Temp mode.
2. The temperature set by the operator.
3. The air temperature inside the
chiller compartment.
4. The temperature of all food probes.
WHEN IN THE HOLD TEMP MODE
AFTER A CHILL MODE:
Press the UP
5
arrow key to display the maximum
sensor temperature achieved during the completed
chill cycle. Press the DOWN
6
arrow key to
display the minimum sensor temperature achieved
during the completed chill cycle. Press the
right
4
or left
3
arrow key to display the Probe
Done Time.
C A U T I O N
NEVER STACK PANS DIRECTLY
ON TOP OF EACH OTHER.
STACKED PANS WILL RESTRICT
AIR FLOW AND INCREASE CHILL
PROCESSING TIME.