Electrical specifications – Alto-Shaam Processing Freezer/Chiller/Refrigeration System QC-3/QC-20/QC-40/QC-50/QC-50 Remote/QC-100/Qc-100 Remote User Manual
Page 14

QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 12.
S U B T I T L E
T I T L E
E L E C T R I C A L
I N S T A L L A T I O N
This appliance must be branch circuit protected
with proper ampacities, in accordance with the
wiring diagram. The Quickchiller must be properly
grounded in accordance with the National Electrical
Code and applicable local codes. Wire size for the
main incoming power to the unit must match the
minimum size listed in the specifications applicable
to the specific Quickchiller model. For supply
connections, locate the wire size listed in this manual.
Before operating the chiller, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
NOTE:
After electrical connections have been
completed, operate the appliance in any
chilling mode for a period of 15 minutes
and recheck the main power connections
at the terminal block to make certain they
remain tight.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
voltage
phase
cycle
/
hz
QC-3
QC-20
QC-40
QC-50
QC-100
SELF-CONTAINED
208-240VAC 1 ph 50/60 Hz
r
ecoMMeNded
circuit
aMperage
:
r
ecoMMeNded
wire
size
:
20 amps
12/2 w.g.
20 amps
12/2 w.g.
30 amps
10/2 w.g.
40 amps
8/2 w.g.
60 amps
6/2 w.g.
n o
c o r d
a n d
p l u g
voltage
phase
cycle
/
hz
QC-3
QC-20
QC-40
QC-50
QC-100
SELF-CONTAINED
208-240VAC 3 ph 50/60 Hz
r
ecoMMeNded
circuit
aMperage
:
r
ecoMMeNded
wire
size
:
Not
available
Not
available
Not
available
20 amps
12/3 w.g.
40 amps
8/3 w.g.
380-415VAC 3 ph 50/60 Hz
r
ecoMMeNded
circuit
aMperage
:
r
ecoMMeNded
wire
size
:
Not
available
Not
available
30 amps
10/2 w.g.
Not
available
30 amps
10/2 w.g.
n o
c o r d
a n d
p l u g
voltage
phase
cycle
/
hz
QC-3
QC-20
QC-40
QC-50
QC-100
REMOTE COMPRESSOR
(Cabinet Only)
208-240VAC 1 ph 50/60 Hz
r
ecoMMeNded
circuit
aMperage
:
r
ecoMMeNded
wire
size
:
Not
available
Not
available
Not
available
20 amps
12/2 w.g.
30 amps
10/2 w.g.
n o
c o r d
a n d
p l u g
ELECTRICAL SPECIFICATIONS
Wire diagrams are located near the top of the unit, close to the compressor or control panel.