Axis Communications 2460 User Manual
Page 29

AXIS 2460 User’s Manual
Setting up Events and Alarms
29
Example 3 - Entry to Boiler Room at night.
This event should be configured as follows:
1. Set the cameras to 1 and 3.
2. Set the alarm activation to Alarm Triggered During Time Period.
3. Set the weekdays and times when the event will be enabled.
4. Set the alarm input settings to 1-Active, 2-----, 3-Active, 4-----.
5. Configure a pre-buffer of e.g. 5 minutes.