beautypg.com

Troubleshooting, American-lincoln 1-59 smart – Nilfisk-ALTO SMART Sweeper/Scrubber 692003 User Manual

Page 59

background image

AMERICAN-LINCOLN

1-59

SMART

TROUBLESHOOTING

PROBLEM

PROBABLE CAUSE

REMEDY

Machine moves slowly or
erratically

Machine does not move

Poor water pickup at
squeegee

Water spills from
squeegee

Squeegee leaves wet
spots

Squeegee makes
excessive noise

1. Battery charge low
2. Brakes dragging
3. Loose connection at foot pedal
4. Drive circuit overloaded

1. Blown fuse
2. Battery unplugged

1. Recovery tank full

2. Squeegee is worn or damaged

3. Clogged suction hose or pick-up tool

4. Loose connections between suction hose

and squeegee

5. Vacuum motors not running

6. Plugged filter

7. Vacuum float cage clogged

8. Vacuum float shut off

9. Air leaks in suction hose and connection

10.Air leaks at recovery tank cover and/or

manifold hose

11.Drain hose or drain plug leakage or not

closed properly

1. Side squeegee blades have poor contact

with floor

2. Squeegee blades worn or damaged
3. Too much solution being applied before

making turns

4. Brushes rotating opposite direction

1. Lift actuator out of adjustment
2. Squeegee wheels out of adjustment

1. Blades worn or damaged

1. Change
2. Adjust
3. Repair
4. Remove obstruction, put drive pedal

in neutral

5. Adjust

1. Check fuse & replace if necessary
2. Plug in battery

1. Empty tank

2. Examine squeegee rubber blade for

cuts or worn spots & replace if
necessary

3. Disconnect suction hose from

squeegee, flush squeegee & hoses

4. Check all hose connections for

looseness or damage

5. Reset circuit breaker or repair loose

connection

6. Clean filter element in vacuum manifold

7. Clean perforated metal thoroughly

8. Excessive solution in recovery tank.

Excessive foam buildup, change
cleaning chemical mixture (use A-L
approved materials)

9. Repair or replace hose and connection

10.Repair or replace seal or hose

11.Close, repair, or replace drain plug

in recovery tank

1. Readjust blades for proper contact

2. Replace & adjust
3. Shut off solution flow 5-10 ft. Before

turning

4. Check switch positions

1. Adjust
2. Adjust

1. Replace