BATTERY REMOVAL
When removing batteries

1.

Lift the machine front cover to access battery compartment.

2.

Unplug the battery power connector from the machine power connector.

3.

Rotate the battery lever to the right.

4.

Lift the battery out using a 2000 LB. (907 KG) capacity lifting device.

BATTERY LEVER

CONNECT A 2000 LB. (907 KG)

CAPACITY LIFTING DEVICE

Fig. 63

Fig. 64

Fig. 65

CONNECTING BATTERY

MAINTENANCE

WARNING

Do not remove the battery from the machine if there is waste in the solution tank.

•••••

Hydrogen gas is formed during the charging operation and is explosive! Only charge
batteries in a well-ventilated area with the lid open. Avoid any open flame or electrical
sparks. Pulling out the charger plug, with the charger still on, will cause an arc and must be
avoided.

•••••

Batteries are heavy. Use lifting device with specified rated capacity.

•••••

Always remove jewelry, wear protective clothing, and face protection when working near
batteries.

•••••

Lead acid batteries generate gases, which cause explosions. Keep sparks and flames away
from batteries charge the batteries only in area with good ventilation. NO SMOKING!

•••••

To prevent an explosion, disconnect the AC plug from the receptacle before connection or
disconnect the DC plug on the charger.

•••••

The battery box can slide off a forklift and cause severe personal injury or damage to
equipment. Ensure that the battery box is properly secured to the forks of the forklift during
transport, drive and stop with caution.

BATTERY COMPARTMENT

Fig. 66