beautypg.com

6 checking the drives for data consistency – Asus Motherboard DSBF-DE/SAS User Manual

Page 138

background image

-

Chapter 5: RAID configuration

5.2.6

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected logical

drive. The utility can automatically detect and/or detect and correct any differences

in data redundancy depending on the selected option in the

Objects > Adapter

menu.

The

Check Consistency command is available only for logical drives included

in a RAID 1 set.

Using the Check Consistency

To check data consistency using the

Check Consistency command:

1. From the

Management Menu, select Check Consistency, then press

.

2. The screen displays the available RAID set(s) and prompts you to select the

logical drive to check. Press the to select the logical drive from

the

Logical Drive selection, then press .