3 cws655 environmental specifications, 5 cws900 specifications, 1 cws900 physical specifications – Campbell Scientific Wireless Sensor Network (CWB100, CWS220, and CWS900) User Manual
Page 21: 2 cws900 electrical specifications

Wireless Sensor Network
2.4.3 CWS655 Environmental Specifications
Temperature Range: -25° to +50°C (-13° F to + 122°F)
Humidity Range:
0 to 100%
Weather Resistance: IP67 rating for sensor and battery pack (battery pack 
 
must be properly installed; each sensor is leak tested)
2.5 CWS900 Specifications
2.5.1 CWS900 Physical Specifications
Dimensions:
15 cm x 6 cm x 4.5 cm (6” x 2.4” x 1.8”)
Weight:
184 g (6.5 oz)
2.5.2 CWS900 Electrical Specifications
Power: 2
AA
Batteries
Average Current Drain:
300
μA with 15 minute polling (depending
on attached sensor)
Radio:
Internal 25 mW FHSS Radio
Single-Ended Analog Channels:
SE1, SE2, SE3
Differential Analog Channels:
DF1
Analog Input Range:
-1 to + 2.5 VDC
Accuracy:
±(0.02% of reading + 2 µV) @ 0° to +50°C; 
±(0.05% of reading + 2 µV) @ -35° to +70°C 
Resolution:
0.3
μV
Excitation Voltage:
2.5V, 3.3 V, 5.0 V 
20 mA maximum 
Excitation Voltage Accuracy:
±2% @ -35° to +70°C
Bridge Measurement Accuracy 
(+2.5 excitation only): 
 
±(0.03% of reading + 3 µV) @ 0° to + 50°C; 
±(0.07% of reading + 3 µV) @ -35° to + 70°C 
Low Level AC Input:
20 mV minimum 
10 kHz maximum frequency 
Switch Closure 
 
Maximum Count Rate:
Minimum Open Time:
Minimum Closed Time:
Maximum Bounce Time:
 
100 Hz 
5 ms 
5 ms 
4 ms 
Temperature Accuracy:
± 0.2ºC
13