5 cws900 wireless sensor interface – Campbell Scientific Wireless Sensor Network (CWB100, CWS220, and CWS900) User Manual
Page 13

Wireless Sensor Network
The CWS655 outputs 8 values: Volumetric water content, Bulk electrical 
conductivity, Dielectric permittivity, Soil temperature, Period Average, 
Voltage ratio, Internal temperature, Battery voltage, and Signal strength. 
Additional detail regarding CWS655 output is available in Appendix B.
For specifications of the CWS655, see Section 2.4.
1.5 CWS900 Wireless Sensor Interface
The CWS900 is a Wireless Sensor Interface. The CWS900 measures analog 
voltages, low level AC, pulse counts, and can supply an excitation voltage for 
powering some sensors or making bridge measurements. It has a sealed 
connector for use with a variety of sensors, such as temperature/humidity 
probes, rain gages, wind monitors, or other low power sensors. The type of 
measurement that the sensor performs is configured using Wireless Sensor 
Planner, Network Planner, or DevConfig software. 
FIGURE 1.5-1. CWS900 Wireless Sensor Interface
The CWS900 outputs 4 - 12 values, depending on configuration. Tables 1.5-1 
and 1.5-2 show available configurations and outputs. 
It is important to note the units of the measurement being made by the 
CWS900. In some cases additional processing of the measurement by the 
datalogger program or post processing in a spreadsheet or database will be 
necessary to convert the measurement to engineering units. 
5