Page 43: 03002 rm young wind sentry wind set, 03002 mounted to the mast, 03002 mounted to cm202, cm204, or cm206, Crossarm, 14. 05103 rm young wind monitor

UT10 Weather Station
FIGURE 8-14. 05103 RM Young Wind Monitor
8.5.3 03002 RM Young Wind Sentry Wind Set
The 03002 can be mounted directly to the mast, or to the CM202, CM204, or
CM206 Crossarm.
8.5.3.1 03002 Mounted to the Mast
1. Slide the crossarm mounting bracket onto the mast. Orient the crossarm so
the vane end points north, and tighten the band clamp (see Section 8.5.17,
Wind Direction Sensor Orientation, for final calibration).
2. Attach the cup assembly to the anemometer shaft using the Allen wrench
provided.
8.5.3.2 03002 Mounted to CM202, CM204, or CM206 Crossarm
Mount the 03002 to the crossarm as shown in FIGURE 8-15.
1. Attach the CM220 bracket on the crossarm via the U-bolt and nuts.
2. Position the top of the mounting post 5 in above the CM220 bracket and
tighten the set screws.
3. Slide the crossarm mounting bracket onto the mounting post. Orient the
crossarm so the vane end points north, and tighten the band clamp (see
Section 8.5.17, Wind Direction Sensor Orientation, for final calibration).
4. Attach the cup assembly to the anemometer shaft using the Allen wrench
provided.