4 sealing and desiccating the enclosure, Sealing and desiccating the enclosure, Rs-232, and cs i/o) to be used at a time – Campbell Scientific UT10 10 foot Tower w/ Grounding Kit and Hinged Base User Manual
Page 40: Figure 8-11), N figure 8-11, In figure 8-11, Figure 8-11

UT10 Weather Station
FIGURE 8-11. You can configure any two types of interface ports
(RS-485, RS-232, and CS I/O) to be used at a time.
8.4 Sealing and Desiccating the Enclosure
Campbell Scientific enclosures include an enclosure supply kit with the
following items:
(4) Desiccant packs
(1) Humidity indicator card
(6) 4-inch cable ties
(6) 8-inch cable ties
(4) Cable tabs
(1) 4 oz. sealing putty
Items in the enclosure supply kit are used to strain relief the sensor leads, seal
cable entry, and desiccate the enclosure (see FIGURE 8-12).
1. Secure the sensor leads to the left side of the enclosure and to the
datalogger using cable ties and tabs.
2. Seal around the sensor leads where they enter the enclosure. Place a roll
of putty around the sensor leads and press it around the leads and into the
coupling to form a tight seal.
3. Remove the RH indicator card and two desiccant packs from the sealed
plastic bag. Remove the backing from the indicator card and attach the
card to the right interior wall of the enclosure.
The humidity indicator card has three colored circles that indicate the
percentage of humidity. Desiccant packs inside the enclosure should be
replaced with fresh packs when the upper dot on the indicator begins to
Connects to a PC via
pn 10873 cable
Connects to the
datalogger CS I/O port
via an SC12 cable
Connects to another MD485
via the CABLE2TP three
conductor 22-AWG cable
30