3 terminal mode – Campbell Scientific PWS100 Present Weather Sensor User Manual
Page 38
![background image](/manuals/416039/38/background.png)
Section 7. Operation
configuration options. These are discussed below within the context of setting
up the sensor using a terminal emulator.
7.3 Terminal Mode
In normal operating mode the sensor will respond to a number of “root”
commands, shown in Table 7-1. Those commands allow the configuration of
the sensor in a non-interactive fashion, the polling of data and also switching
the sensor into an interactive user menu mode.
They are accessed via the command TERM PWS_1d Password
↵
Commands are entered in the format ‘Command Pws_1d Password
↵
TABLE 7-1. Command Set
Command Description
PASSWORD Sets
user
password
HELP*
Gives a list of available commands
OPEN* Activate
user
menu
TERM
Enter command mode
CLOSE Exit
command
mode
MSEND* Poll
messages
MSET
Set message parameters
HDATA
Retrieve historical particle data from sensor
SETPARAM Set
weather
parameters
FUZZY DIAG* Extra particular information (see Section 7.5.2)
CONFIG View
system configuration
SETCONFIG
Set system configuration
LOADOS
Load a new operating system
DIAGSET
Set diagnostic test parameters
DIAG
Run diagnostic test
TIME
Display or set time and date
RSENSOR
Receive remote sensor values (T °C and H %)
RESET Reset
hardware
XHMDATA
Historic `MSET’ data download using Xmodem
HMDATA
Output historic data to the command line
RUNDISC
Rotate the calibration disc for test / demonstration
purposes
*These commands are available outside terminal mode.
The most commonly used commands are MSEND, HELP and OPEN.
7-2