Section 5. Specifications
5.3 Optical Specifications
5.3.1 Laser Head Specifications
Laser Source:
Near-infrared (IR) diode, eye safe Class 1M
unit output
Peak Wavelength:
830 nm
Modulation Frequency:
96 kHz
Laser Head Lens Diameter: 50 mm (1.97 in)
5.3.2 Sensor Head Specifications
Receivers:
Photodiode with band pass filters
Spectral Response:
Maximum spectral sensitivity at 850 nm, 0.62
A/W (0.6 A/W at 830 nm)
Sensor Head Lens Diameter: 50 mm (1.97 in)
Lens Check Light Source:
Near-IR LED
5.4 Environmental Specifications
Standard Operating
Temperature Range:
-25
° to +50°C
Optional Extended Operating
Temperature Range:
-40
° to +70°C
Relative Humidity Range:
0 to 100%
IP Rating:
IP 66 (NEMA 4X)
5.5 CS215-PWS Specifications
Please refer to the CS215 manual or product brochure for the specifications.
5.6 Measurement Capabilities and Limitations
5.6.1 Visibility Measurements
Visibility Range:
0 to 20,000 m (0 to 65,620 ft)
Visibility Accuracy:
± 10% (0 to 10,000 m)
Measurement Interval:
User selectable from 10 seconds to 2 hours