Appendix A. CM245 Adjustable Angle Mounting Stand

FIGURE A-2. CM245 bracket with 1.5 in. U-bolts positioned to mount

pyranometer at a 40° angle on a vertical pipe

Do the following to level the pyranometer horizontally:

1. Attach the mounting stand to the crossarm.
2. Loosely mount the pyranometer on the mounting stand. Do not fully

tighten the two mounting screws.

3. Turn the leveling screws as required to bring the bubble of the level within

the ring.

4. Tighten the mounting screws to secure the assembly in its final position.

Check that the pyranometer is still correctly leveled and adjust as necessary.

First

1.5 in

U-bolt

Second

1.5 in

U-bolt

40

pn 17446

pn 4365

pn 4366

pn 27291

pn 17446

1.50 in

A-2