HMP155ATemperature and Relative Humidity Probe

current at 12 volts. Approximately 2 seconds is required for the sensor to

warm up after power is switched on. At measurement rates slower than once

per 5 seconds, the overall power consumption (datalogger and sensors) may be

reduced by switching power to the HMP155A. Most current Campbell

Scientific dataloggers have a built-in switched 12 volts that can be used to

control power.

HMP155 sensors purchased directly from Vaisala with serial

numbers < E4430001 require approximately 5 seconds warm up

time.

The CR9000, CR510, CR500, CR7, CR10, and 21X dataloggers do not have a

built-in switched 12 V. Users with these dataloggers can power the sensor

continuously or purchase the model SW12V to switch power.

The -L option on the model HMP155A Temperature and Relative Humidity

probe (HMP155A-L) indicates that the cable length is user specified. TABLE

5-1 gives the recommended lead length. Add 2 ft to the cable length if the

enclosure is mounted to the leg base of a CM106B, CM110, CM115, or

CM120 tripod.

TABLE 5-1. Recommended Lead Lengths

2 m Height

Atop a tripod or tower via a 2 ft crossarm

Mast/Leg

CM202

CM106B CM110 CM115 CM120 UT10 UT20 UT30

9 ft

11 ft

14 ft

14 ft

19 ft

24 ft

14 ft

24 ft

37 ft

The probe’s cable can terminate in:

Pigtails that connect directly to a Campbell Scientific datalogger

(option –PT).

Connector that attaches to a prewired enclosure (option –PW). Refer

to

www.campbellsci.com/prewired-enclosures

for more information.

6. Specifications

Features:

Well-suited for long-term, unattended applications

Accurate and rugged

Compatible with Campbell Scientific CRBasic dataloggers:

CR200(X) series, CR800 series, CR1000, CR3000, CR5000, and

CR9000(X). Also compatible with Edlog dataloggers: CR500,

CR510, CR10(X), CR23X, 21X, and CR7

Operating temperature range

for humidity measurement:

–80° to +60°C –112° to +140°F)

Storage temperature range:

–80° to +60°C –112° to +140°F)

Electromagnetic compatibility: Complies with EMC standard EN61326-1,

Electrical equipment for measurement