HMP155A Temperature and Relative Humidity Probe

2. Squeeze the sides of the white connector cover and insert the cable’s

connector through it (see FIGURE 4-2).

FIGURE 4-2. Cable routed through the connector cover

3. Attach the cable to the mating connector on the bottom of the HMP155A

(see FIGURE 4-3).

FIGURE 4-3. Cable connected to the sensor

4. Slide the white connector cover over the connector and gently push it up as

far as it will go. The white connector cover has built-in molded stops that

will only allow it to slide up so far. See FIGURE 4-4.

FIGURE 4-4. HMP155A with connector cover in place and without

protective cap

5. Loosen the split-nut on the bottom plate of the 41005-5 14-plate radiation

shield.

6. Remove the yellow protective cap on the HMP155A, and insert the sensor

into the shield.

7. Tighten the hex plug such that it compresses against the body of the

HMP155A to hold it inside the 41005-5 radiation shield.

8. If mounting the 41005-5 directly to a mast, place the 41005-5 U-bolt in the

side holes and secure the 41005-5 to the mast by tightening the U-bolt nuts

(FIGURE 4-5).

9. If using a CM200-series crossarm, mount the crossarm to the tripod or

tower. Then place the 41005-5’s U-bolt in the bottom holes and secure the

41005-5 to the crossarm by tightening the U-bolt nuts (see FIGURE 4-6).

10. Route the cable to the datalogger, and secure the cable to the mounting

structure using cable ties.