I-3

12. Hold the new PROM by either end as

shown in Figure I-6. Position the PROM
over the sockets with the circular notch on
the end of the PROM oriented the same
direction as the surrounding PROMs.

ItemNo 6146

ObjslNo

C

1984

FIGURE I-6. Inserting the New PROM

CAUTION: The notch must be on the right
side. Inserting the PROM in the wrong
direction can damage it.

Set the pins of the PROM on the individual
sockets and press gently. Make sure
individual pins are being inserted straight
into the socket clips and are not bending.
Gently push the PROM in until it seats fully
in the socket.

NOTE: Inspect the PROM assuring that
none of the pins have been bent or are not
in the socket.