beautypg.com

Tgt1 transmitter specifications, Required equipment, 1 computer base station – Campbell Scientific DCP100 GOES Data Collection Platform User Manual

Page 10: 2 field station

background image

DCP100 DATA COLLECTION PLATFORM

2

Phone

modem

NESDIS

Wallops Station, VA

ground station has

10 asynchronous

dial circuits

communication/power cable

Antenna cable

Environmental enclosure

Phone

line

Computer Base Station

Transmitter

Power
supply

Datalogger

Data Collection Platform

Yagi antenna

FIGURE 2-1. Data Retrieval Diagram

3. TGT1 TRANSMITTER

SPECIFICATIONS

Output level: +40 dBm (10 watts), +1.0 dBm
at 12 VDC with automatic leveling control

Typical current drain: 9 mA quiescent, 2200
mA active

Operating temperature range:

40

°

to +60

°

C

Supply voltage range: 10.5 to 14.0 VDC

Dimensions: 3.5" x 7.2" x 4.4" (8.9 x 18.3 x
11.2 cm)

Weight: 2.1 lbs (1.0 kg)

Self-timed buffer: 2000 bytes

Random buffer: 2000 bytes

Transmission rate: 100 bits per second

Typical number of data points transmitted:
118 for a 1 minute transmit-window (with 15
second guard bands)

Maximum EIRP allowed by NESDIS: +50 dB

Antenna's maximum gain: +9 dB with right-
hand circular polarization, +12 dB with linear
polarization.

Clock accuracy: Capable of running 420 days
without adjustment.

4. REQUIRED EQUIPMENT

4.1 COMPUTER BASE STATION

The equipment required at the computer base
station is listed below.

Phone modem with MNP level 4 error
correction. (Most commercially available
Hayes-compatible modems contain this
error-checking protocol. Check the
operator's manual for your modem).

Computer with user-supplied commu-
nication software (e.g., Procomm Plus,
Crosstalk).

4.2 FIELD STATION

The field stations equipment is illustrated in
Figures 4-1 and 4-2. The required equipment is
listed below.

TGT1 satellite transmitter.

Datalogger (CR23X, CR10X, CR500,
CR510, CR10, or 21X). A CR10KD
keyboard/display is required when using a
CR10X, CR10, CR510, or CR500. The
CR10 and 21X require a special PROM.
When using a 21X with both a TGT1 and a
storage module (SM192, SM716, or CSM1),
hardware and datalogger programming
modifications are required. Contact a
Campbell Scientific applications engineer
for more information.

Yagi antenna, mounting bracket, and
coaxial cable.

Weather-proof enclosure.

12 Volt power supply, charging regulator, and
a solar panel.

A filter is also required when measuring
sensor(s) requiring equalization with the
atmosphere (e.g., vented pressure transducers,

NESDIS

Wallops Station, VA

ground station has

10 asynchronous

dial-up circuits

,+2