Campbell Scientific DCP100 GOES Data Collection Platform User Manual
Page 23

DCP100 DATA COLLECTION PLATFORM
15
;{21X}
;
*Table 1 Program
01:
10.0
Execution Interval
(seconds)
;Measure reference temperature.
01:
Internal Temperature (P17)
1:
1
Loc [ RefTemp ]
;Measure thermocouple temperature.
02:
Thermocouple Temp (DIFF) (P14)
1:
1
Reps
2:
1
± 5 mV Slow Range
3:
5
DIFF Channel
4:
1
Type T (Copper-Constantan)
5:
1
Ref Temp Loc [ RefTemp ]
6:
2
Loc [ TCDef_F ]
7:
1.8
Mult
8:
32
Offset
;Measure battery voltage every 10 seconds.
03:
Batt Voltage (P10)
1:
3
Loc [ Battery ]
;Set Output Flag High (10) every hour
04:
If time is (P92)
1:
0
Minutes into a
2:
60
Minute Interval
3:
10
Set Output Flag High
;Designate 111 as ID for hourly data
05:
Set Active Storage Area (P80)
1:
1
Final Storage
2:
111
Array ID or Loc
[ _________ ]
;Timestamp data
06:
Real Time (P77)
1:
220
Day,Hour/Minute (prev day
at midnight, 2400 at
midnight)
;Output hourly the average reference Temp, TC
Temp, and battery voltage.
07:
Average (P71)
1:
3
Reps
2:
1
Loc [ RefTemp ]
;Sample the forward and reflected power.
08:
Sample (P70)
1:
2
Reps
2:
1
Loc [ RefTemp ]
;Transfer data to TGT1 every hour.
09:
If time is (P92)
1:
0
Minutes into a
2:
60
Minute Interval
3:
30
Then Do
;Transfer data array ID 111 to the TGT1's self-
timed buffer and places the transmitter's latest
forward and reflected power readings into Input
Locations 4 and 5.
10:
Data Transfer to GOES (P99)
1:
00
Buffer Selection
2:
4
FWD/Ref Power Loc
[ FwdPwr ]
3:
111
Array ID (ID>0) Transferred
to TGT1'S Buffer
11:
End (P95)
;Set Output Flag High (10) for daily output
12:
If time is (P92)
1:
0
Minutes into a
2:
1440
Minute Interval
3:
10
Set Output Flag High
;Timestamp data
13:
Real Time (P77)
1:
220
Day,Hour/Minute (prev day
at midnight, 2400 at
midnight)
;Designate 222 as the array ID.
14:
Set Active Storage Area (P80)
1:
1
Final Storage
2:
222
Array ID or Loc
[ _________ ]
;Average, maximize, and minimize the reference
and TC temperatures, battery voltage, and the
forward and reflected power readings.
15:
Average (P71)
1:
5
Reps
2:
1
Loc [ RefTemp ]
16:
Maximize (P73)
1:
5
Reps
2:
0
Value Only
3:
1
Loc [ RefTemp ]
17:
Minimize (P74)
1:
5
Reps
2:
0
Value Only
3:
1
Loc [ RefTemp ]
;Sends data to the TGT1 once a day. Note: this
is set for 5 minutes after midnight to give ample