DCP100 DATA COLLECTION PLATFORM

15

;{21X}
;
*Table 1 Program

01:

10.0

Execution Interval
(seconds)

;Measure reference temperature.
01:

Internal Temperature (P17)

1:

1

Loc [ RefTemp ]

;Measure thermocouple temperature.
02:

Thermocouple Temp (DIFF) (P14)

1:

1

Reps

2:

1

± 5 mV Slow Range

3:

5

DIFF Channel

4:

1

Type T (Copper-Constantan)

5:

1

Ref Temp Loc [ RefTemp ]

6:

2

Loc [ TCDef_F ]

7:

1.8

Mult

8:

32

Offset

;Measure battery voltage every 10 seconds.
03:

Batt Voltage (P10)

1:

3

Loc [ Battery ]

;Set Output Flag High (10) every hour
04:

If time is (P92)

1:

0

Minutes into a

2:

60

Minute Interval

3:

10

Set Output Flag High

;Designate 111 as ID for hourly data
05:

Set Active Storage Area (P80)

1:

1

Final Storage

2:

111

Array ID or Loc
[ _________ ]

;Timestamp data
06:

Real Time (P77)

1:

220

Day,Hour/Minute (prev day
at midnight, 2400 at
midnight)

;Output hourly the average reference Temp, TC
Temp, and battery voltage.
07:

Average (P71)

1:

3

Reps

2:

1

Loc [ RefTemp ]

;Sample the forward and reflected power.
08:

Sample (P70)

1:

2

Reps

2:

1

Loc [ RefTemp ]

;Transfer data to TGT1 every hour.
09:

If time is (P92)

1:

0

Minutes into a

2:

60

Minute Interval

3:

30

Then Do

;Transfer data array ID 111 to the TGT1's self-
timed buffer and places the transmitter's latest
forward and reflected power readings into Input
Locations 4 and 5.
10:

Data Transfer to GOES (P99)

1:

00

Buffer Selection

2:

4

FWD/Ref Power Loc
[ FwdPwr ]

3:

111

Array ID (ID>0) Transferred
to TGT1'S Buffer

11:

End (P95)

;Set Output Flag High (10) for daily output
12:

If time is (P92)

1:

0

Minutes into a

2:

1440

Minute Interval

3:

10

Set Output Flag High

;Timestamp data
13:

Real Time (P77)

1:

220

Day,Hour/Minute (prev day
at midnight, 2400 at
midnight)

;Designate 222 as the array ID.
14:

Set Active Storage Area (P80)

1:

1

Final Storage

2:

222

Array ID or Loc
[ _________ ]

;Average, maximize, and minimize the reference
and TC temperatures, battery voltage, and the
forward and reflected power readings.
15:

Average (P71)

1:

5

Reps

2:

1

Loc [ RefTemp ]

16:

Maximize (P73)

1:

5

Reps

2:

0

Value Only

3:

1

Loc [ RefTemp ]

17:

Minimize (P74)

1:

5

Reps

2:

0

Value Only

3:

1

Loc [ RefTemp ]

;Sends data to the TGT1 once a day. Note: this
is set for 5 minutes after midnight to give ample