16

transfer time for the hourly data initiated by the
P99 in instruction 10.

18:

If time is (P92)

1:

5

Minutes into a

2:

1440

Minute Interval

3:

30

Then Do

19:

Data Transfer to GOES (P99)

1:

00

Buffer Selection

2:

4

FWD/Ref Power Loc
[ FwdPwr ]

3:

222

Array ID (ID>0) Transferred
to TGT1'S Buffer

20:

End (P95)