beautypg.com

1 heated rain gage – Campbell Scientific CS700 Tipping Bucket Rain Gage and CS700H Heated Rain Gage User Manual

Page 7

background image

CS700 and CS700H Rain Gage

2.1 Heated Rain Gage

Snow Sensor and Heater
Operating Temperature Range:
-20° to +5°C

Output: SDI-12

Voltage Requirements
Main

Power:

10 to 30 Vdc or 12 to 28 Vac

SDI-12

Power:

9.6 to 16 Vdc

Total Current Consumption (See Figure 2-1)

Snow sensor off, heater off: 6 mA @ 12 V, 0.072 W

Snow sensor on, heater off: 12 mA @ 12 V, 0.144 W

Snow sensor on, heater on: 5.8 A @ 12 V, 70 W

As the ambient temperature falls below the “Active On Temperature” (default
4°C), the heater will turn on to heat the funnel area of the rain gauge. Once the
funnel reaches the “Funnel Set Point Temp” (default 10°C), the heater will
begin cycling on and off with a duty cycle dependent on the ambient
temperature, keeping the funnel temperature at or near 10°C.

FIGURE 2-1. Heater Operation

3