2 cs700h heated rain gage connections – Campbell Scientific CS700 Tipping Bucket Rain Gage and CS700H Heated Rain Gage User Manual
Page 14

CS700 and CS700H Rain Gage
4.2 CS700H Heated Rain Gage Connections
The CS700H sensor cable can be wired to the datalogger’s pulse channels (see
Table 4-3). The sensor cable can also be wired to the datalogger control ports
instead of pulse channels (see Table 4-4).
TABLE 4-3. CS700H Sensor Cable Wiring for Pulse Channel Inputs
Color
Description
CR800, CR850,
CR1000,
CR3000,
CR5000
CR10X, CR23X
Green SDI-12 SDI-12
compatible
Control Port
(e.g., C1,
C3, C5, C7)
SDI-12
compatible
Control Port
(e.g., C1-C8)
Red 12V 12V 12V
Black 0V
G
G
Blue
Signal A
Pulse Channel
(e.g., P1, P2)
Pulse Channel
(e.g., P1, P2)
White Signal
Reference
G
Yellow
Signal B
Pulse Channel
(e.g., P1, P2)
Pulse Channel
(e.g., P1, P2)
Brown Signal
Return
G
TABLE 4-4. CS700H Sensor Cable Wiring for Control Port Inputs
Color
Description
CR800, CR850,
CR1000,
CR3000,
CR5000
CR10X, CR23X
Green SDI-12 SDI-12
compatible
Control Port
(e.g., C1,
C3, C5, C7)
SDI-12
compatible
Control Port
(e.g., C1-C8)
Red 12V 12V 12V
Black 0V
G
G
Blue
Signal A
Control Port
(e.g., C1-C8)
Control Port
(e.g., C1-C8)
White 5V
5V
5V
Yellow
Signal B
Control Port
(e.g., C1-C8)
Control Port
(e.g., C1-C8)
Brown 5V
5V
5V
10