beautypg.com

2 cs700h heated rain gage connections – Campbell Scientific CS700 Tipping Bucket Rain Gage and CS700H Heated Rain Gage User Manual

Page 14

background image

CS700 and CS700H Rain Gage

4.2 CS700H Heated Rain Gage Connections

The CS700H sensor cable can be wired to the datalogger’s pulse channels (see
Table 4-3). The sensor cable can also be wired to the datalogger control ports
instead of pulse channels (see Table 4-4).

TABLE 4-3. CS700H Sensor Cable Wiring for Pulse Channel Inputs




Color




Description

CR800, CR850,
CR1000,
CR3000,
CR5000




CR10X, CR23X

Green SDI-12 SDI-12

compatible
Control Port
(e.g., C1,
C3, C5, C7)

SDI-12
compatible
Control Port
(e.g., C1-C8)

Red 12V 12V 12V
Black 0V

G

G

Blue

Signal A

Pulse Channel
(e.g., P1, P2)

Pulse Channel
(e.g., P1, P2)

White Signal

Reference

G

Yellow

Signal B

Pulse Channel
(e.g., P1, P2)

Pulse Channel
(e.g., P1, P2)

Brown Signal

Return

G

TABLE 4-4. CS700H Sensor Cable Wiring for Control Port Inputs




Color




Description

CR800, CR850,
CR1000,
CR3000,
CR5000




CR10X, CR23X

Green SDI-12 SDI-12

compatible
Control Port
(e.g., C1,
C3, C5, C7)

SDI-12
compatible
Control Port
(e.g., C1-C8)

Red 12V 12V 12V
Black 0V

G

G

Blue

Signal A

Control Port
(e.g., C1-C8)

Control Port
(e.g., C1-C8)

White 5V

5V

5V

Yellow

Signal B

Control Port
(e.g., C1-C8)

Control Port
(e.g., C1-C8)

Brown 5V

5V

5V

10