5. Attach each leg assembly to the tripod body using two ¼-20 x 1.75” bolts
and nylock nuts. Attach the two grounding clamps using #10-32 x 0.75”
bolts. Do not over-tighten the bolts. The tripod legs and leg braces must be
able to pivot.
1/4-20 x 1.75” Bolt
1/4-20 x 1.75” Bolt
1/4-20 Nylock Nut
1/4-20 Nylock Nut
Grounding Clamp
#10-32 x 0.75” Bolt
Grounding Clamp
#10-32 x 0.75” Bolt
Leg
Leg Brace
Leg
Tripod Body
2.2 Tripod Base Positioning
Tripod installation near power lines is dangerous. The
minimum safe recommended distance from overhead
power lines is 1½ times the height of the tripod and
mast combined. Call your local utility providers to
locate buried utilities prior to installation.
WARNING
The tripod base has three legs, which are individually adjustable, that allow the
tripod to be installed over non-level terrain.
6