5 long lead lengths – Campbell Scientific 03001-L R.M. Young Wind Sentry Set User Manual

Page 15

background image

R.M. Young Wind Sentry

7: If (X<=>F) (P89)
1: 3

X Loc [ WindDir ]

2: 3

>=

3: 360

F

4: 30

Then

Do


8: Z=F x 10^n (P30)

1: 0

F

2: 0

n, Exponent of 10

3: 3

Z Loc [ WindDir ]


9: End (P95)

10: If (X<=>F) (P89)
1: 3

X Loc [ WindDir ]

2: 4

<

3: 0

F

4: 3

Then

Do


11: Z=F x 10^n (P30)

1: 0

F

2: 0

n, Exponent of 10

3: 3

Z Loc [ WindDir ]


12: End (P95)

13: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


14: Set Active Storage Area (P80)^15464
1: 1

Final Storage Area 1

2: 101

Array

ID


15: Real Time (P77)^6687
1: 1220

Year,Day,Hour/Minute (midnight = 2400)


16: Wind Vector (P69)^28601
1: 1

Reps

2: 0

Samples

per

Sub-Interval

3: 0

S, theta(1), sigma(theta(1)) with polar sensor

4: 2

Wind Speed/East Loc [ WS_ms ]

5: 3

Wind Direction/North Loc [ WindDir ]

5.5 Long Lead Lengths

When sensor lead length exceeds 100 feet, the settling time allowed for the
measurement of the vane should be increased to 20 milliseconds.

11