beautypg.com

Specifications, Installation, 1 siting – Campbell Scientific 024A-L Met One Wind Direction Sensor User Manual

Page 13: Siting

background image

024A Met-One Wind Direction Sensor

6. Specifications

Compatible Dataloggers: CR200(X)

CR800

series

CR1000

CR3000

CR5000

CR9000(X)

CR510

CR10(X)

CR23X

CR7

21X

Range:

0 to 360 degrees

Threshold:

0.447 m s

-1

(1.0 mph)

Accuracy: ±5

degrees

Temperature Range:

-50° to +70°C

Delay Distance:

Less than 1.5 m (5 ft.)

Damping Ratio

Standard: 0.25

Optional: 0.4

Potentiometer Specifications

Sand, Dust, and Fungus: MIL-E-5272

Salt Spray: MIL-E-12934

Resistance:

0 to 10,000 ohms

Weight:

450 g (1 lb)

Dimensions

Overall Height:

33.8 cm (13.3 in)

Overall Length:

44.7 cm (17.6 in)

Tail Height:

30.5 cm (12 in)

Tail Width:

7.6 cm (3 in)

7. Installation

7.1 Siting

Locate wind sensors away from obstructions (e.g. trees and building). As a
general rule of thumb there should be a horizontal distance of at least ten times
the height of the obstruction between the windset and the obstruction. If it is
necessary to mount the sensors on the roof of a building, the height of the
sensors, above the roof, should be at least 1.5 times the height of the building.
See Section 9, References, for a list of references that discuss siting wind
direction sensors.

7