Specifications, Installation, 1 siting – Campbell Scientific 024A-L Met One Wind Direction Sensor User Manual
Page 13: Siting

024A Met-One Wind Direction Sensor
6. Specifications
Compatible Dataloggers: CR200(X)
CR800
series
CR1000
CR3000
CR5000
CR9000(X)
CR510
CR10(X)
CR23X
CR7
21X
Range:
0 to 360 degrees
Threshold:
0.447 m s
-1
(1.0 mph)
Accuracy: ±5
degrees
Temperature Range:
-50° to +70°C
Delay Distance:
Less than 1.5 m (5 ft.)
Damping Ratio
Standard: 0.25
Optional: 0.4
Potentiometer Specifications
Sand, Dust, and Fungus: MIL-E-5272
Salt Spray: MIL-E-12934
Resistance:
0 to 10,000 ohms
Weight:
450 g (1 lb)
Dimensions
Overall Height:
33.8 cm (13.3 in)
Overall Length:
44.7 cm (17.6 in)
Tail Height:
30.5 cm (12 in)
Tail Width:
7.6 cm (3 in)
7. Installation
7.1 Siting
Locate wind sensors away from obstructions (e.g. trees and building). As a
general rule of thumb there should be a horizontal distance of at least ten times
the height of the obstruction between the windset and the obstruction. If it is
necessary to mount the sensors on the roof of a building, the height of the
sensors, above the roof, should be at least 1.5 times the height of the building.
See Section 9, References, for a list of references that discuss siting wind
direction sensors.
7