1-4. battery voltage indicator, 1-5. ovp : over voltage indicator, 1-6. uvp : under voltage protection indicator – Samlex America SA-1500 User Manual
Page 8: 1-7. otp : over temperature protection indicator, 1-8. olp : over load protection indicator, 1-10. ac outlet (outlet sockets available)
6
3-1-4. Battery Voltage indicator
The AC load watt bar graph indicates the power drawn from the power
inverter by the load. For long term operation, the watt indicator
should remind in the green & orange area of the bar graph.
Short term operation is possible with watt indicator in the red area.
If the watt indicator rises to high values the bar will flash and the
inverter will shutdown to protect itself.
3-1-5. OVP : Over Voltage indicator
The over voltage indicator indicates that the power inverter has shut
itself down because its input voltage exceeded 12 / 24 VDC version.
3-1-6. UVP : Under Voltage Protection indicator
The under voltage indicator indicates that the power inverter has shut
itself down because its input voltage fell below 12 / 24 VDC.
3-1-7. OTP : Over Temperature Protection indicator
The over temp indicator indicates that the power inverter has shut itself
down because its temp has become overheated. The power inverter
may overheat because it has been operated at power levels above its
rating, or because it has been installed in a location which does not
allow it to dissipate heat properly. The power inverter will restart
automatically, once it has cooled off.
3-1-8. OLP : Over Load Protection indicator
The overload indicator indicates that the power inverter has shut itself
down because its output has been short circuited or drastically
overloaded.
Switch the ON/OFF switch to OFF, correct the fault condition, and then
switch the ON/OFF switch back to ON to reset the unit.
3-1-9. Power Saving: Power energy saving enable.
See appendix 9-2 for detailed information.
3-1-10. AC Outlet (Outlet sockets available):