2-2-2. command format, This unit supports the following commands, 2-2-3. pwrs command – Samlex America SA-1500 User Manual
Page 24: Power saving function control, Format: pwrs < value, Value > can be one of the following, 0”:power saving disable, 1”:power saving enable, 2-2-4. power command, Power on/off control
22
8-2-2-2. Command format
This unit supports the following commands.
There should always be a CR (0DH) and a LF (0AH)
appended to the command while sending the command to his
unit.
8-2-2-3. PWRS command
:
Power saving function control
Format
: PWRS < value>
Illustration
:A space (ASCll code 20H) is needed between
PWRS and < value >
< value > can be one of the following
“0”
:Power saving disable
“1”
:Power saving enable
“2”
:Inquire the status of saving the response information
would be either “0” (disable) or “1” (enable)
8-2-2-4. Power command
Power ON/OFF control
Format
:Power < value>
Illustration
:A space (ASCll code 20H) is needed between
PWRS and < value >
< value > can be one of the following
“0”
:Power off, power consumption < 2W, restart time < 5 sec
“1”
:Power off, power consumption <20W, restart time < 2
sec
“2”
:Power on
“3”
:Inquire the status of power on/off status, the response
information would be either “0” (OFF) or “1” (OFF) or “2”
(ON)