Switch on the front plate of the inverter is done as follows:

This procedure acts as a toggle i.e. If the inverter was in

enabled state before the procedure, it will switch to disabled

state after the procedure.

Likewise, if it was in disabled state before the procedure, it will

switch to enabled state after the procedure.
Switch off all the loads, switch off the inverter, disconnect all

loads. Switch on the inverter. There will be 2 beeps and

green led will start flashing with a flashing sequence of flash-

flash-flash… (it will flash for approx. 3 seconds).

Immediately after it starts flashing, switch off the power on /

off switch and immediately switch on again. This will complete

the switching procedure. The inverter will continue its power

on sequence and switch over to the new state.
The power on / off switch should be switched off and on again

during the time the green led is flashing (the green led will

flash with a sequence of flash-flash-flash… For about 3

seconds after the inverter is powered on).