beautypg.com

Ventilation, Installation location, 3 cm to electric or gas cookers – Siemens KI27FP60 User Manual

Page 23: 30 cm to an oil or coal-fired cooker, Connecting the appliance, Electrical connection

background image

en

23

The climate class can be found on

the rating plate. Fig.

-

Note
The appliance is fully functional within

the room temperature limits

of the indicated climatic class. If

an appliance of climatic class SN

is operated at colder room temperatures,

the appliance will not be damaged up to

a temperature of +5 °C.

Ventilation

Fig.

1/20

The refrigeration unit is ventilated only via

the ventilation grille in the base. Never

cover the ventilation grille or place

anything in front of it. Otherwise the

refrigeration unit must work harder,

increasing the power consumption.

Installation location

Install the appliance in a dry, well

ventilated room. The installation location

should neither be exposed to direct

sunlight nor near a heat source, e. g.

a cooker, radiator, etc. If installation next

to a heat source is unavoidable, use

a suitable insulating plate or observe

the following minimum distances to a

heat source:

3 cm to electric or gas cookers.

30 cm to an oil or coal-fired cooker.

Connecting

the appliance

After installing the appliance, wait at least

1 hour until the appliance is switched on.

During transportation the oil in the

compressor may have flowed into the

refrigeration system.
Before switching on the appliance for the

first time, clean the interior of the

appliance (see chapter “Cleaning the

appliance”).

Electrical connection

The socket must be near the appliance

and also freely accessible following

installation of the appliance.
The appliance complies with the

protection class I. Connect the appliance

to 220–240 V/50 Hz alternating current

via a correctly installed socket with

protective conductor. The socket must

be fused with a 10 to 16 A fuse.
For appliances operated in non-

European countries, check whether the

stated voltage and current type match

the values of your mains supply. This

information can be found on the rating

plate. Fig.

-

ã=

Warning

Never connect the appliance to

electronic energy saver plugs.
Our appliances can be used with mains

and sine-controlled inverters. Mains-

controlled inverters are used for

photovoltaic systems which are

connected directly to the national grid.

Sine-controlled inverters must be used

for isolated applications (e.g. on ships or

in mountain lodges) which are not

connected directly to the national grid.

Climate class

Permitted ambient

temperature

SN

+10 °C to 32 °C

N

+16 °C to 32 °C

ST

+16 °C to 38 °C

T

+16 °C to 43 °C