beautypg.com

6 set debounce time, 7 set auto repeat mode – Matrix Orbital VK204-25 Legacy User Manual

Page 42

background image

Remembered

No

9.6

Set Debounce Time

Syntax

Hexadecimal

0xFE 0x55 [time]

Decimal

254 85 [time]

ASCII

254 “U” [time]

Parameters

Parameter

Length

Description

time

1

Debounce time in increments of
6.554ms (0 - 255).

Description

This command sets the time between key press and key read. All key
types with the exception of latched piezo switches will ’bounce’ for a
varying time, depending on their physical characteristics. The [time]
value is in increments of 6.554ms. The default debounce time for the
module is 8 (about 52ms), which is adequate for most membrane
keypads.

Remembered

Yes

Default

8

9.7

Set Auto Repeat Mode

Syntax

Hexadecimal

0xFE 0x7E [mode]

Decimal

254 126 [mode]

ASCII

254 “~” [mode]

Parameters

Parameter

Length

Description

mode

1

Auto Repeat Mode (0: Resend Key
, 1: Key Up/Down)

Matrix Orbital

VK204-25

38