7.2

General Purpose Output Off

Syntax

Hexadecimal

0xFE 0x56 [Num]

Decimal

254 86 [Num]

ASCII

254 “V” [Num]

Parameters

Parameter

Length

Description

Num

1

GPO number.

Description

This command turns OFF general purpose output [num].

NOTE

OFF means that the output is pulled LOW.

Remembered

Yes

7.3

General Purpose Output On

Syntax

Hexadecimal

0xFE 0x57 [Num]

Decimal

254 87 [Num]

ASCII

254 “W” [Num]

Parameters

Parameter

Length

Description

Num

1

GPO number.

Description

This command turns ON general purpose output [num]. The standard
GPO’s on the VK204-25 output 20mA of current at 5V.

NOTE

ON means the output is pulled HIGH.

Remembered

Yes

7.4

Set Startup GPO state

Syntax

Hexadecimal

0xFE 0xC3 [Num] [state]

Decimal

254 195 [Num] [state]

Parameters

Parameter

Length

Description

Num

1

GPO number.

state

1

Startup state (0: Off, 1: On)

Matrix Orbital