Maintenance, 10 reassembly / maintenance, Reassembly / maintenance – Wagner PaintREADY Spray Gun User Manual
Page 10: Start important, Cup seal
English
10
Reassembly /
Maintenance
Start
Important:
You should inspect the air filters in the turbine
to see if it is excessively dirty. If it is dirty,
follow these steps to replace it.
IMPORTanT: never operate your unit without
the air filters. Dirt could be sucked in and
interfere with the function of the unit.
* Cup seal
It is important that the cup seal inside the spray
gun be re-installed properly. Make sure the cup
side of the seal (the side with the groove) is facing
out towards the front of the spray gun.
Groove
4. Unplug the spray gun. Push the snap levers (a) on the two
turbine covers and remove them.
Remove the dirty filters and replace with new ones. The
smooth side of the air filter must be placed toward the
turbine.
Secure the covers back onto the turbine.
1. Install the cup seal with the
groove (slot) facing toward the
nozzle*.
Insert the nozzle, keeping an eye
on the grooves (a).
2. Put the air screen (b) in the air cap
(c). Put both on the nozzle (d) and
secure with the connecting nut
(e).
3. Snap the adjustment ring (f) into
the connecting nut, enabling the
loop on the peg to be positioned
in the air cap.
Reassemble the spray gun.
(a)
(a)
1
4
(b)
(d)
(c)
(e)
2
(f)
3