beautypg.com

12 appendix a - marking codes, 1 atex mark, 2 iecex mark – Videotec EXPT User Manual

Page 19: 1 atex mark 12.2 iecex mark, 2g ex d ee c t6 gb

background image

EN - English - I

nstruc

tions manual

17

12 Appendix A - Marking codes

12.1 ATEX Mark

ee

2G Ex d eeC T6 Gb

ee

2D Ex t eeeC T85°C Db IP66

Fig. 10

Group (surface
device, no
mining)

Category (high
protection
degree, the
device in this
category can be
installed in zones
1 and 2)

Gas

Explosion-proof
housing for potentially
explosive environments

Gas group

Gas temperature
classification

Protection level of the
equipment for gas

Group (surface
device, no
mining)

Category (high
protection
degree, the
device in this
category can be
installed in zones
21 and 22)

Dust

Dust ignition protection
for zone types 21-22

Dust group

Maximum surface
temperature for dusts

Protection level of the
equipment for dust

IP protection degree

Tab. 01

12.2 IECEx Mark

Ex d eeC T6 Gb
Ex t
eeeC T85°C Db IP66

Fig. 11

Explosion-proof
housing for
potentially explosive
environments

Gas group

Gas temperature
classification

Protection level of the
equipment for gas

Dust ignition
protection for zone
types 21-22

Dust group

Maximum surface
temperature for dusts

Protection level of the
equipment for dust

IP protection degree

Tab. 02