Preliminary start-up check, Start-up – Burr King BK75 User Manual
Page 27
Donaldson Company, Inc.
26
Preliminary Start-Up Check
1. Check all electrical connections for tightness
and contact.
2. Check for and remove all loose items in or near
the inlet and outlet of the unit.
3. Check that all remote controls are wired into
the control system, and all service switches are
in the OFF position.
4. Check that all optional accessories are installed
properly and secured.
5. Check that hopper discharge is open and the
storage container is sealed, if equipped. Excess
airflow to the blower will cause electrical
failure.
6. Turn power ON at source.
7. Turn the fan motor ON then OFF to check for
proper rotation by referencing the rotation
arrow located on the motor’s mounting plate.
To reverse rotation, single-phase power supply:
Follow manufacturer’s instructions on the
motor’s nameplate.
To reverse rotation, three-phase power supply:
Turn electrical power OFF at source and switch
any two leads on the output-side of the fan-
motor starter.
Start-Up
1. Turn power ON at source.
2. Turn unit ON.
3. On hopper models with 5- or 55-gallon drum
storage, check that hopper discharge is open
and the storage container is sealed, if equipped.
Excess airflow to the blower will cause
electrical failure.
4. When airflow diminishes, turn the unit OFF and
manually shake the EZ Filter Pack.