En 44 – Siemens KG49NSW31 User Manual
Page 44
en
44
Fault
Possible cause
Remedial action
The temperature in
the freezer
compartment is too
warm.
Appliance opened
frequently.
Do not open the appliance
unnecessarily.
The ventilation
openings have been
covered.
Remove obstacles.
Large quantities of
fresh food are being
frozen.
Do not exceed max. freezing
capacity.
Freezer compartment
door was open
for a long time;
temperature is no
longer reached.
The evaporator
(refrigeration
generator)
in the No Frost system
is covered in thick ice
and can no
longer be defrosted
fully automatically.
To defrost the evaporator, remove
the frozen food
with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move
it away from the wall. Leave
the appliance door open.
After approx. 20 min.
the condensation begins to run
into the evaporation pan,
at the rear of the appliance. Fig. +
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation
with a sponge.
The evaporator is defrosted when
the water stops running
into the evaporation pan. Clean
the interior. Switch the appliance
back on again.