beautypg.com

Eliminating minor faults yourself – Siemens GI38NP60 User Manual

Page 33

background image

en

33

Eliminating minor faults yourself

Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following

information.
Customer service will charge you for advice – even if the appliance is still under

guarantee!

Fault

Possible cause

Remedial action

Temperature differs

greatly from the set

value.

In some cases it is adequate to

switch off the appliance

for 5 minutes.
If the temperature is too high wait a

few hours and check whether the

temperature has approached the set

value.
If the temperature is too low check

the temperature again the next day.

Displays do not

illuminate.

Power failure; the fuse

has been switched off;

the mains plug has not

been inserted

properly.

Connect mains plug. Check whether

the power is on, check the fuses.

The refrigerating unit

is switching on more

frequently and for

longer.

Appliance opened

frequently.

Do not open the appliance

unnecessarily.

The ventilation

openings have been

covered.

Remove obstacles.

Appliance is not

cooling, temperature

display and light

are lit.

Showroom mode is

switched on.

Hold down alarm button, Fig

2/1,

for 10 seconds until an

acknowledgement signal sounds.
After a short time check whether

your appliance is cooling.

The light does not

function.

The LED light

is defective.

See chapter “Light (LED)” section.

Appliance was open

too long.
Light is switched off

after approx. 10 min.

When the appliance is closed