Observe room temperature, Installing the appliance, Ventilation – Siemens KI34NP60 User Manual
Page 26
26
Observe room
temperature
The appliance is designed for a specific
climatic class. Irrespective of the climatic
class, the appliance can be operated at
the following room temperatures.
The climatic class can be found on the
rating plate at the bottom leftĆhand side
in the appliance.
Climatic class
Ambient temperature
SN
+10
°C to 32 °C
N
+16
°C to 32 °C
ST
+16
°C to 38 °C
T
+16
°C to 43 °C
Ventilation
Fig. 1/23
Conduction of the heated air must not be
obstructed. Otherwise, the refrigerating
unit must work harder. This increases
power consumption.
Therefore: Never cover or block ventilation
opening!
Installing the appliance
Install the appliance in a dry, well
ventilated room. The installation location
should neither be exposed to direct
sunlight nor near a heat source, e.g.
a cooker, radiator, etc. If installation next
to a heat source is unavoidable, use
a suitable insulating plate or observe the
following minimum distances to a heat
source:
3 cm to electric or gas cookers.
30 cm to an oil or solidĆfuel cooker.