Power failure, The fuse has been switched off, The mains plug has not been inserted properly – Siemens KI24LV21FF User Manual
Page 32: En 32
en
32
Fault
Possible cause
Remedial action
The refrigerating unit
is switching on more
frequently and for
longer.
Appliance opened
frequently.
Do not open the appliance
unnecessarily.
The ventilation
openings have been
covered.
Remove obstacles.
Large
quantities of fresh
food are being frozen.
Do not exceed max. freezing
capacity.
The frozen food is
thawing.
The ambient
temperature is below
+16° C. The
refrigeration unit is
starting less
frequently.
Increase the ambient temperature
(above +16° C).
Fig.
2/B Appliances with room
temperature switch: To switch on,
press the room temperature switch.
Mark “0” is no longer visible.
The light inside the appliance is lit
at a reduced luminosity.
Appliance has no
refrigeration capacity.
The temperature
controller is in position
“0”.
Turn the temperature controller from
position “0”. Fig.
2/A
■
Power failure.
■
The fuse has been
switched off.
■
The mains plug has
not been inserted
properly.
Check whether the power is on,
check the fuses.