Observe ambient

temperature

and ventilation

Ambient temperature

The appliance is designed for a specific

climatic class. Depending on the climatic

class, the appliance can be operated at

the following room temperatures.
The climatic class can be found on

the rating plate, Fig.

9.

Room temperature switch
If the room temperature drops

below 16 °C, the freezer compartment

of appliances belonging to climatic

class SN may become too warm.

In an extreme case the frozen food may

thaw. To prevent this from happening,

switch on the room temperature switch.

As a result, the refrigerating unit

operates more frequently. The appliance

can now be operated at a room

temperature of +10 °C to +16 °C.
To switch on, press the room

temperature switch, Fig.

2/B. Mark “0”

is no longer visible. The light inside

the appliance is lit at a reduced

luminosity.
To save energy, switch off the room

temperature switch as soon as the room

temperature exceeds +16 °C.

Ventilation

The air on the rear panel of

the appliance heats up. Conduction of

the heated air must not be obstructed.

Otherwise, the refrigeration unit must

work harder. This increases power

consumption. Therefore: Never cover

or block the ventilation openings!

Installation location

Install the appliance in a dry, well

ventilated room. The installation location

should neither be exposed to direct

sunlight nor near a heat source, e. g.

a cooker, radiator, etc. If installation next

to a heat source is unavoidable, use

a suitable insulating plate or observe

the following minimum distances to a

heat source:

3 cm to electric or gas cookers.

30 cm to an oil or coal-fired cooker.

Climatic class

Permitted ambient

temperature

SN

+10 °C to 32 °C

N

+16 °C to 32 °C

ST

+16 °C to 38 °C

T

+16 °C to 43 °C