beautypg.com

Information concerning the water filter, Specification and output data sheet – Siemens KA58NA45 User Manual

Page 34

background image

34

Information concerning
the water filter

- After use, the water system is subĆ

ject to low pressure. Proceed with
caution when removing the filter.

- Flush the water system if the appĆ

liance has not been in use for a
lengthy period, or if the ice/water
has an unpleasant taste or smell.
To do this, dispense water through
the water dispenser for several
minutes. If the unpleasant taste or
smell remains, replace the filter.

Protect from frost. Remove the filter
cartridge if you expect the temperaĆ
ture to drop below freezing.

Do not install the water filter if the
water pressure is greater than
0.86 MPa (8.6 bar).
If the water pressure is greater than
0.55 MPa (5.5 bar), a pressure
reducing valve must be fitted. If you
are not sure what the water pressure
is, contact an installation expert.

If pressure surges could occur in the
water pipe, do not install the water
filter without a suitable surge
eliminator. Contact an installation
expert if you are not sure whether
pressure surges could occur in the
water pipe.

- After installing a new filter:

Discard any ice produced in the first
24 hours after switching on.

- If no ice has been removed for a

lengthy period: Empty the ice box
and discard any ice produced over
the next 24 hours.

- The ice and water dispenser can

also be used without a water filter,
in which case the locking cap must
be used.

1.

2.

Specification and output data sheet

Performance Data Sheet

Models CSĆ451/CSĆ452

These systems have been tested according to NSF/ANSI 42 for the reduction of the substances listed below.

The concentration of the substances indicated in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42.

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
chlorine taste and odour.

Capacity: 5,700 litres depending on local water conditions.

Contaminant reduction determined by NSF testing

Contaminant
reduction

Average

influent

NSF specified influent

challenge concentration

Avg. product

water

Avg. %

reduction

NSF reduction

requirements

NSF Test

Chlorine taste and odour

2.0

2.0 mg/l

± 10%

0.28

86

≥ 50%

503821Ć01

For cold water use only.

Application guidelines / water supply parameters

It is essential that operational maintenance and filter

Service flow

1.9 l/min

It is essential that operational, maintenance and filter
replacement requirements be carried out for this

Water supply

Public or private well

replacement requirements be carried out for this
product to perform as advertised. Change cartridges

Water pressure

0.17 Ć 0.86 MPa (1.7 Ć 8.6 bar)

product to perform as advertised. Change cartridges
every 6 months. Flush new cartridge for 5 minutes.
Use replacement cartridges CS 51 or CS 52

Water temperature

5 Ć 38 °C

Use replacement cartridges CSĆ51 or CSĆ52.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.

Warranty: See warranty card.

For service and parts contact your local dealer or:

Note that while the testing was performed under standard
laboratory conditions, actual performance may vary.

p

y

 2003 CUNO Incorporated
INSTR4906 0203 [EN 2008]

CUNO Incorporated

400 Research Parkway

Meriden, CT 06450, USA

Worldwide: 203Ć237Ć5541

Fax: 203Ć238Ć8701

www.cuno.com

en