General specification – Notifier Lumidor Minimax XT User Manual
Page 3

General Specification
Standard Specification
General
Disposable single gas monitor for the protection of personnel against toxic and Oxygen gas hazards
Maximum Operating Life
2 years after activation
Shelf Life
12 months before activation (CO and H
2
S), 6 months before activation (O
2
)
Sensor Range
Carbon Monoxide CO
0 to 1000 ppm (display: 0-200 ppm)
Hydrogen Sulphide H
2
S
0 to 100 ppm (display: 0-100 ppm)
Oxygen
O
2
0 to 30%v/v (display: 0-25.0%v/v)
Alarm Set Points
CO
35 ppm
100 ppm
(Note: Other alarm settings
H
2
S 10
ppm
15
ppm
are available upon request)
O
2
23.5%
19.5%
Calibration CO/H
2
S Zero
adjustment
(optional
Span)
O
2
Span
adjustment
Operating Temperature
-4°F to +122°F (-20°C to +50°C)
Humidity
5-95% RH (non-condensing)
Audible Alarm
95db at 4in (10cm)
Visual Alarm
High intensity red LEDs
Vibrating Alarm
Supplied as standard
Display Custom
LCD
Sensor Type Electrochemical
Battery
3.6V non-replaceable Lithium battery
IP Rating
IP67 (NEMA 4 & 6)
Intrinsic Safety
Europe: II 2G EEx ia IIC T4 (ATEX)
UL/cUL: Class 1, Div 1, Groups A, B, C, D T4
RFI/EMC
CE EN50270:1999 and EN55011
Dimensions
3.4"(H) x 2"(W) x 1.1"(D)
(87mm x 50mm x 27mm)
Weight CO/H
2
S 73g
(2.57oz)
O
2
82.3g
(2.90oz)
*Reflex
TM
not available for all sensors
Display Details
Test pass icon
Level 2, CO, H
2
S
Level 1, CO, H
2
S, O
2
Level 2, O
2
Life time: Months, days, hours
Concentration units
Low peak
High peak
Test Fail icon
Life time, alarm reading
Battery
1 l
ev
e
L
2 l
ev
e
L
* Oxygen detection products must only be used
to detect oxygen depletion in air.