General specification, Display details – Notifier Lumidor Minimax XP User Manual
Page 3

General specification
Standard Specification
Alarm Set Points
Gases Detected
Range
Level 1
Level 2
STEL
TWA
Oxygen (O
2
)
0 to 30% v/v
23.5% v/v
19.5% v/v
n/a
n/a
Carbon Monoxide (CO)
0 to 999 ppm
35 ppm
100 ppm
400 ppm
35 ppm
Hydrogen Sulphide (H
2
S)
0 to 250 ppm
10 ppm
15 ppm
15 ppm
10 ppm
Sulphur Dioxide (SO
2
)
0 to 150 ppm
2 ppm
5 ppm
5 ppm
2 ppm
Chlorine (Cl
2
)
0 to 50 ppm
0.5 ppm
1 ppm
1 ppm
0.5 ppm
Hydrogen Cyanide (HCN)
0 to 100 ppm
5 ppm
10 ppm
10 ppm
5 ppm
Nitrogen Dioxide (NO
2
)
0 to 150 ppm
3 ppm
5 ppm
5 ppm
3 ppm
Ammonia (NH
3
)
0 to 100 ppm
25 ppm
50 ppm
35 ppm
25 ppm
Hydrogen (H
2
)
0 to 999 ppm
100 ppm
500 ppm
n/a
n/a
Construction
General
Serviceable, portable single gas monitor for personal protection against Oxygen and toxic gas hazards
Calibration
Time between calibrations is maximized utilizing cell decay compensation facility.
The maximum time between calibrations is 12 months
#
Operating Life
Sensor (replaceable) Minimum of 2 years
Battery (replaceable) 3 years*
Operating Temperature
-20°C to +50°C (-4°F to +122°F) (temperature compensated)
Humidity 5-95%
RH
(non-condensing)
Audible Alarm
95dB @ 10cm (3.9")
Visual Alarm
High intensity Red LEDs
Vibrating Alarm Standard
Display
Ultra clear backlit LCD displays gas levels & instrument status
Sensor Type Electrochemical
(replaceable)
Battery Type
Lithium CR2, 3.0v (replaceable)
Diagnostics
Self-test of circuitry, battery, LCD, and software. Sensor test using patented Reflex
†
sensor technology
Environmental
IP Rating IP54
(minimum)
Intrinsic Safety
North America: Class 1, Div 1, Groups A, B, C, D, T4 (UL/cUL)
Europe: II 2G EEx ia IIC T4 (ATEX)
RFI/EMC
CE EN50270:1999 and EN55011
Dimensions
93mm (H) x 50mm (W) x 27mm(D)
(3.6" x 2" x 1.1") excluding clip
Weight
Toxic
81.5g (2.8oz)
Oxygen
93.0g (3.3oz)
*Operating Life may be reduced by excessive alarms
†
Reflex not available on all sensors
#
H
2
S/CO only
Display Details
A
C
B
I
F
G
D
H
E
J
A
Battery
Fail
Self-test pass icon
Level 1: O
2
and toxics
Level 2: Toxics
Level 2: O
2
STEL/TWA alarm
Cal. Status icon
Low peak (O
2
), High peak
(O
2
and toxics)
Gas concentration and units
Alarm icon
B
C
D
E
F
G
H
I
J
* Oxygen detection products must only be
used to detect oxygen depletion in air.