PHYSICAL SPECIFICATIONS
Height: 13.25 inches (33.7 cm).
Width: 13.0 inches (33 cm).
Depth: 5.0 inches (12.7 cm).
SLC Connection: Standard SLC connections. Class B (for-
merly Style 4) or Class A (formerly Style 6/7).
Relays: 8 Form C, 3 AMP, programmable latching or non-
latching.
Communication Network: Ethernet monitoring, 6 E-mail
address alerts, Modbus/TCP.
Cable Access: 4 1-inch (2.54 cm) cable entry holes on top
and bottom of unit.
Wire Gauge: 12 AWG (2.05 mm) max. to 24 AWG (0.5 mm)
min.
Maximum Single Pipe Length: 262 ft. (80 m).
Maximum Branched (2) Pipe Length: 165 ft. (50 m) each
branch.
Maximum Air Inlet Holes: 40 holes.
Network Outside Pipe Diameter: 1.050 inches, IPS (25 mm).
Internal Pipe Diameter: 0.591 to 0.827 inches (15-21 mm).
Sensitivity Range: 0.00046%/ft. obs – 4.0%/ft. obs.
Event Log: 18,000 events stored.
Shipping Weight: 11.6 lbs. (5.26 kg), includes packing mate-
rial.
User Interface Display:
• Five alarm levels (Alert, Action 1, Action 2, Fire 1, and
Fire 2).
• Ten particulate levels.
• Ten bi-color flow.
• Fault graph.
Agency Listings and Approvals
The listings and approvals below apply to Intelligent FAAST
Series components. In some cases, certain modules or applica-
tions may not be listed by certain approval agencies, or listing
may be in process. Consult factory for latest listing status.
•
UL Listed: S911.
•
ULC Listed: S911.
•
FM approved.
•
Maryland State Fire Marshal: Permit # 2244.
Product Line Information
8100 Intelligent FAAST: Conventional aspirating smoke
detector. For Canadian applications, order 8100A.
F-A3384-000: Replacement Air Filter.
F-LCARD-SP: Language Card - Spanish.
P-PIPE-210: CPVC Pipe (210 feet total).
P-COUPLING: Coupling (15 each).
P-ELB-45: 45° Elbow (10 each).
P-ELB-90: 90° Elbow (20 each).
P-ENDCAP: End Cap (25 each).
P-TEE: Tee (15 each).
P-UNION: Union (10 each).
P-LABEL-P: Pipe Label (100 each).
P-LABEL-T: Sampling Point Labels (100 each).
P-SAMP-KT: Sampling Point Kit (10 sets).
HP300ULX: Power Supply, 12/24VDC, 2.4 A DC.
User Interface Display