Recommended coverage per detector, Installation, Agency listings and approvals – Notifier FSL-751 User Manual
Page 2: Product line information

Page 2 of 2 — DN-6886:C • 07/12/2012
NOTIFIER®, FlashScan®, and VIEW® are registered trademarks of
Honeywell International Inc.
FlashScan® and VIEW® are registered trademarks of Honeywell
International Inc.
©2012 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com
Made in the U.S. A.
Recommended Coverage Per Detector
In order to support sophisticated smoke/dust discrimination
algorithms (cooperating multi-detector), it is recommended
that at least two FSL-751 detectors be installed in each room
or enclosed area.
Recommended coverage per detector is 400 square feet
(37.16 square meters).
Installation
The FSL-751 plug-in detector uses a separate base to simplify
installation, service, and maintenance. A special tool allows
maintenance personnel to plug in and remove detectors with-
out using a ladder.
Mount base on a box which is at least 1.5" (38.1 mm) deep.
Suitable mounting base boxes include:
• 4" (101.6 mm) square box.
• 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box.
• Single-gang box (except relay or isolator base).
Agency Listings and Approvals
These listings and approvals apply to the modules specified in
this document. In some cases, certain modules or applications
may not be listed by certain approval agencies, or listing may
be in process. Consult factory for latest listing status.
•
UL Listed: S1115.
•
ULC Listed: S1115.
•
MEA Listed: 128-07-E (NFS2-640, NFS-320); 3-02-E.
•
FM Approved.
•
CSFM: 7272-0028:0218
•
BSMI: CI313066760036.
•
CCCF: Certif. # 2004081801000015.
When used with NFS2-640/NFS-320, MARINE-EQ, and
appropriate seismic bracket, these detectors are approved by
the following agencies:
– U.S. Coast Guard: 161.002/50/0 (Standard 46 CFR).
– Lloyd's Register: 11/600013 (ENV 3 category).
Product Line Information
NOTE: “A” suffix indicates ULC Listed model.
FSL-751(A): Laser Detector. Intelligent laser sensor with
FlashScan® capabilities. Mounts to one of the bases listed
below.
INTELLIGENT BASES
NOTE: “A” suffix indicates ULC Listed model.
NOTE: For details on intelligent bases, see DN-60054.
B210LP
(A)
: Standard U.S. flanged low-profile mounting base.
B210LPBP: Bulk pack of B210LP; package contains 10.
B501
(A)
: Standard European flangeless mounting base.
B501BP: Bulk pack of B501; package contains 10.
B200S
(A)
: Intelligent, programmable sounder base capable of
producing sound output in high or low volume with ANSI Tem-
poral 3, ANSI Temporal 4, continuous tone, marching tone,
and custom tone.
B200SR
(A)
: Intelligent sounder base capable of producing
sound output with ANSI Temporal 3 or continuous tone.
Replaces B501BH series bases in retrofit applications.
B224RB
(A)
: Plug-in System Sensor relay base. Screw termi-
nals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0
A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @
30 VDC inductive.
B224BI(A): Plug-in System Sensor isolator detector base.
Maximum 25 devices between isolator base.
ACCESSORIES
RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to
a U.S. single-gang electrical box. For use with B501(A) and
B210LP(A) bases only.
SMB600: Surface mounting kit.
M02-04-00:Test magnet.
M02-09-00: Test magnet with telescoping handle.
XR2B: Detector removal tool. Allows installation and/or
removal of detector heads from bases in high ceiling applica-
tions.
XP-4: Extension pole for XR2B. Comes in three 5-foot
(1.524 m) sections.
MOD400R: Detector sensitivity test tool. Use with most analog
or digital multimeters. Satisfies requirement of NFPA72 for
sensitivity testing.