Agency listings and approvals, Product line information – Notifier 411UDAC Rev 2 Fire Alarm Communicator User Manual
Page 3
DN-60797:A • 10/8/13 — Page 3 of 4
Agency Listings And Approvals
These listings and approvals apply to the modules specified in
this document. In some cases, certain modules or applications
may not be listed by certain approval agencies, or listing may
be in process. Consult factory for latest listing status.
•
UL Listed: S624.
•
CSFM: 7300-0075:0174.
•
MEA: 328-94-E Volume VI.
Product Line Information
411UDAC: Four-channel, dual-line, stand-alone or slave Fire
Alarm Communicator. Includes housing, operating and pro-
gramming instructions. Use PRO-411 (below) hand-held
DACT programmer for local programming; or PK-411UD
(below) Windows-based programming software for remote pro-
gramming and real-time diagnostics.
PRO-411
Optional hand-held DACT programmer which
can be used to troubleshoot and program the 411UDAC, as
well as access the various modes of operation.
PK-CD
Contains PK-411UD programming software.
The PK-411UD enables a user to program the 411UDAC off-
site via the public switched telephone network using a per-
sonal computer.
TR-6-R: Optional Trim Ring.
MCBL-7: DACT phone cord, seven feet long (two required).
BAT-1270: Battery, 12-volt, 7.0 AH (one required for 24-hour
systems; two (wired in parallel) required for 60-hour systems.
The following table contains UL listed receivers compatible
with the 411UDAC’s onboard DACT.
(1) With version 3.9 software.
(2) With 685-8 Line Card with Rev. 4.4d software.
(3) With 9002 Line Card Rev. 9035 software or 9032 Line Card
with 9326A software.
(4) With 124077V2.00 Receiver and 126047 Line Card Rev. M.
(5) With V.7301 Receiver S/W.
(6) With 01.01.03 Receiver S/W and Line Card 01.01.03.
(7) Surgard System III software version 1.6.
(8) Surgard MLR-2 software version 1.86.
(9) With DSP4016 and V1.6 Line Card.
(10) With 124060V206B and 124063 Line Card Rev. B
Format #
(Addresses 20 and 50)
FB
I
CP220F
B (1
)
Adem
co
68
5 (2)
S
ile
nt K
n
ig
ht
900
0 (3)
S
ile
nt K
n
ig
ht
980
0 (4)
Osb
o
rn
e Hof
fm
an
2000E (
5)
Rad
ion
ics
660
0 (6)
Surgar
d
Syst
em II
I (7)
Sur
g
uard
MLR
-2 (8
)
Sur
g
uard
MR
-2000 (9)
Adem
co
MX8000
(10)
0
4+1 Ademco Express
1
4+2 Ademco Express
2
3+1/Standard/1800/2300
3
3+1/Expanded/1800/2300
4
3+1/Standard/1900/1400
5
3+1/Expanded/1900/1400
6
4+1/Standard/1800/2300
7
4+1/Expanded/1800/2300
8
4+1/Standard/1900/1400
9
4+1/Expanded/1900/1400
A
4+2/Standard/1800/2300
B
4+2/Expanded/1800/2300
C
4+2/Standard/1900/1400
D
4+2/Expanded/1900/1400
E
Ademco Contact ID
Compatible UL Listed Receivers