beautypg.com

Display, Time, Vi-d5000 ir dome – Videoswitch CMOR Vi-D5000 Dome User Manual

Page 32

background image

Vi-D5000 IR Dome

Videoswitch Page

27

VD601A.DOC

DAY/NIGHT TIME:

Selectable range is 2 - 15 seconds

IR PWR STBY:

IR power standby can be set to 1-9 level when the dome camera is in idle
time, which can improve the life of IR lamps.

IR TIME STBY:

The time interval from the no any operation to dome camera to the
effective operation to it.

ILLUMINATION ON:

Its range is 0-25 level. In the IR mode of auto, when the “ILLUMINATION
ON” is lower than ”AMBIENT LIGHT”, the picture turns to colour and IR
lamps close. When “ILLUMINATION ON” is higher than “AMBIENT
LIGHT”, likewise, the picture turns to night and IR lamps switch on.

AMBIENT LIGHT:

This function is system data and can’t be changed. It updates
automatically for the ambient light in the range of 50 level.

4.6 Display

ADDR:

It displays ON or OFF.

ZOOM:

It can be selected as ON or OFF.

P/T:

It can be selected as ON or OFF.

ACT:

It displays the current action, such as set preset, call preset, 360°scan. ON
or OFF can be selected.

TIME:

It has ON and OFF modes.

IR: “☀” means displaying the open status of IR and can be seen at the top left corner of screen. Open the IR
display progress bar “ ”, which will be filled gradually along with the illumination level.

4.7 Time

DATE:

Set the system date.

TIME:

Set the system time.

SCHEDULE:

There are preset 1-8, A-B scan, 360° scan, guard tour preset, pattern, no
action selectable.

Example of Schedule:

1. 8 schedules can be set. First, select the schedule needing to be set and press the right key to enter the

setting status.

2. Use the up and down keys to adjust the present value, and press the right key to enter and come to the

next adjustment. The item being changed will blink. When it blinks, operate the right key again to exit the
editing the schedule. While press the left key to give up operation.

3. Select the next schedule and repeat the operations above.

4. When setting the status, press left key to exit setting. When selecting the status, press left key to return to

the previous page.