5 Technical Data
5.1 Vi-D4 Domes
5.1.1 Camera
Sony Ex-View Had ¼” CCD
18:1, 28:1 or 36:1 optical zoom and optional 12:1 digital zoom
Resoltion: 550TVL
5.1.2 IR
Illumination
Double-hetero AlGaAs LEDs
830nm wavelength (optional 940nm fully covert)
Degradation estimated at 3% per year
5.1.3 Power
requirements
24V DC, 2.5Amps Maximum
5.1.4 Physical
and
Environmental
Colour
Grey (custom colours may be ordered)
Operating Temperature
-35degC to 50degC
Environmental IP66
Dimensions/Weight
252.4mm x 485mm x 225.8mm (HxWxD), 4.32kg
Dimensions/Weight (Boxed)
385mm x 300mm x 300mm (HxWxD), 4.72kg
5.2 Vi-PSU-1A Power Supply
5.2.1 Power
Input
100 to 240 Vac 50/60Hz
Output 24Vdc,
2.5A
5.2.2 Alarm Module Selection
When the alarm module is plugged in, the RS485 input from the controller will be
automatically routed to the alarm module, and the RS485 output of the alarm module will be
automatically routed to the dome.
5.2.3 Physical
and Environmental
Environmental IP66
Dimensions/Weight
230mm x 140mm x 100mm (LxWxD), 1kg
Dimensions/Weight (Boxed)
340mm x 225mm x 140mm (LxWxD), 1.3kg
5.2.4 Safety
For safety reasons, the internal metal cover must not be removed. There are no user